BINDER VD115UL-120V Series VD - Vacuum Drying Chambers, For Non-Flammable Solvents, 9630-0007
Quick Overview
Heating-up time to 100 °C [min]: 130 Temperature fluctuation [± K]: 0.1 Temperature range +10 °C above ambient temperature to [°C]: 220 Temperature range +9 °C above ambient temperature to [°C]: 220 Temperature variation at 100 °C [± K]: 2.9
Details
Benefits
Fast, gentle drying Optimum heat transfer through large thermal conducting plates Safe work thanks to proven safety concept Also option of modular complete system with vacuum pump and pump chamber
Important characteristics
Temperature range: +9 °C above ambient temperature to +220 °C Controller with digital display of pressure and temperature Program-controlled drying monitoring with automatic ventilation at end of process Internal data logger, measured values can be read out in open format via USB 1 aluminum expansion rack, can be custom-positioned Inert gas connection Universal access port DN 16 - for the introduction of external measuring devices Shatterproof, spring-mounted safety glass panel Large viewing window with option of interior lighting Computer interface: Ethernet
Optional equipment
Touchscreen Controller - Graphical display of main process parameter Expansion racks - Choice of aluminum or stainless steel racks depending on the application requirements Analogue output for temperature and pressure signals - for external monitoring and evaluation of the process parameters, integration into in-house systems is possible Universal ventilation - Selection of different ventilation by air or inert gas Universal access port DN 40 - for the introduction of external measuring devices Multi Management Software APT-COM - Manage, record and document device parameters Services - extensive services ensure correct device function
Technical specifications
Performance Data Temperature:
Heating-up time to 100 °C [min]: 130 Temperature fluctuation [± K]: 0.1 Temperature range +10 °C above ambient temperature to [°C]: 220 Temperature range +9 °C above ambient temperature to [°C]: 220 Temperature variation at 100 °C [± K]: 2.9
Vacuum Data
Leak rate [bar/h]: 0.01
Electrical data
Nominal power [kW]: 1.6 Phase (Nominal voltage): 1~ Power frequency [Hz]: 50/60 Rated Voltage [V]: 100…120 Unit fuse [A]: 10
Connections
Compressed air connection for pressure-encapsulation [NW]: 5 Measuring access port with small flange [DN mm]: 16 Universal connection for air / inert gas with flow limiter thread (RP") 3/8: 3/8 Vacuum connection with small flange [DN mm]: 16
Doors
Unit doors: 1
Housing dimensions not incl. fittings and connections
Depth net [in]: 22.89 Height net [in]: 37.11 Width net [in]: 29.27